MS1700 – Oil in Water Analyzer

System Specifications
Detection Range 1 ppm to 100 ppm

Display Range Default 0 ppm to 100 ppm configurable during commissioning

Repeatability 5% to +5% see Note 1

Accuracy 15% to +15% see Note 1

Measurement Frequency Continuous with optional modes of 15 20 30 and 60 minutes available upon request

Ambient Temperature 0 °C 32 °F to 40 °C 104 °F see Note 2

Water Temperature 1 °C 34 °F to 40 °C 104 °F see Note 2

Analog Output 4 mA to 20 mA scalable to the required range with a maximum load of 900 Ω

Analog Output Isolation 400 V DC

Relay Voltage Maximum 50 V with alarm and fault relays featuring NO contacts

Relay Current Maximum 5 A

Service Interface USB A to PC using the provided Multisensor Software

Data Storage Uses a μSD card with up to 6 months of storage capacity

Instrument Case Rated IP65 NEMA 4X

Instrument Weight 5 kg 11 lbs

Instrument Dimensions 300 x 200 x 132 mm 11 8 x 7 8 x 5 2 inches

Sampling Chamber Material Stainless steel with PVC available as an option

Sampling System Weight 12 kg 26 lbs without water

Sampling System Dimensions 570 x 490 mm 22 x 19 inches mounted on its own PVC backboards

Sampling System Capacity 3 liters 0 79 US gallons

Flow Limit Switch Contacts close if flow falls below the set point option available upon request

Water Flow Rate 2 lmin 0 52 US gpm

Supply Voltage

AC Version 90 V AC to 240 V AC 50 Hz or 60 Hz
DC Version 10 V DC to 15 V DC
Power Consumption

Maximum 9 W
Typical during operation 7 W
Note 1 ±15% accuracy from 20 to 100 ppm measured using a 50 ppm toluene solution at standard temperature and pressure

Note 2 Climate control may be required depending on process and ambient conditions

11 People watching this product now!
  • Ini demo, bisa diisi apa saja
  • Ini demo, bisa diisi apa saja
  • Ini demo, bisa diisi apa saja
  • Ini demo, bisa diisi apa saja
  • Produk Tridinamika tersertifikasi jaminan SNI

Ini hanya demo

Free

  • Jasa Pengiriman kilat oleh tim Tridinamika

Ini hanya demo saja

2-3 Days

Free

Product Details

Specification

The MS1700 is an on line oil in water analyzer designed to detect and measure hydrocarbon concentrations in water up to 100 mgl in industrial processes refineries and petrochemical complexes

Using a state of the art contactless technology the MS1700 provides a solution that is not affected by turbidity and can detect all the volatile hydrocarbons independently from their fluorescence properties

Applications
Oil detection in Cooling Water
Oil detection in produced water
Detection of phenols in discharge water
Effluent monitoring
Pre filtration monitoring
Oil in wastewater
Filter protection

Features and benefits
No sensor contact with water low maintenance no sensor cleaning
Measures both Polycyclic Aromatic Hydrocarbons PAHs and VOCs
Electronic Nose not affected by turbidity
Can be calibrated for specific substances used to monitor known spills
Catches fluorescent and non fluorescent compounds
Alarms to SCADA and other communication interfaces
For more information on the principle of operation click on the FAQs tab

Request a Quote

The MS1700 oil in water analyzer is designed to detect concentrations of up to 100 mgl and it’s used in a variety of applications such as

Oil in cooling water
Hydrocarbons are an ever present class of compounds in industrial processes factories and industrial plants of all sorts A leaking piece of equipment a corroded heat exchanger a leaking diesel pump or simply an accidental spill can mean that cooling water gets contaminated with hydrocarbons When this happens an oil in water analyzer like the MS1700 can help to detect contamination in the cooling water early on before it creates major issues

Phenols
Phenols are widely used in industry as one of the starting material to produce plastics explosives and drugs however they can be harmful for the environment and companies that deal with phenols need to comply with very strict emission limits

Influent water
Wherever water and hydrocarbons get mixed together in a process refineries petrochemical processes etc there is a need to treat this water before it’s used further down in the process or discharged into the environment This influent water has usually got high levels of hydrocarbon and depending on the incoming level the treatment can be optimised

Additional information
Brand

Multisensor

User Manual

Contact Us