Program-Controlled Three Phase Standard Power Source GF303 GFuve

GF303 Program-controlled three phase AC standard power source is a high precision three phase AC standard current source and AC standard voltage source.

Description

GF303 Program-controlled three phase AC standard power source is a high precision three phase AC standard current source and AC standard voltage source. According to DL/T 2213.1-2021 AC standard power source Part 1:General requirements. It is suitable for power department, metrology department, quality control department, research units, institutions of higher learning, electric energy meter, power distribution terminals, power supply management, load control, power quality, reactive power compensation device and the production of enterprise etc.

FEATURES

  • To set up and take the load regulation of voltage, current, phase angle, frequency and power factor, also can be used as AC current source, AC voltage source or power source.
  • To set 2-128 times of the amplitude and phase harmonics, and it can be added to the base wave in every harmonic output.
  • Frequency value is adjustable (AB and phase C).
  • Voltage, current output a wide range, big power, high stability, waveform distortion degree is small.
  • Strong with load ability, but it can take capacitive, sensibility, resistance of composite type load or load and load regulation is higher than 0.01%.
  • To apply the 32 bit MPU + DSP + FPGA, powerful flexible.
  • To use hardware PID, fast response, the change of load will not cause output volatility.
  • Industrial frequency waves as high as 50000 points a week of the wave kneading, signal output without filter, precise output waveform, the harmonic output precision, harmonic distortion degree is small.
  • Range switching automatically
  • To use software calibration, simple operation, stable and reliable.
  • To have big screen, 320 x 240 LCD display, Chinese or English interface, operating simply.
  • To have perfect over-current, over-voltage, heat, a shorts-and-opens, overload protection, failure detection automatically.
  • With RS232 interface, and PC connection
  • To take place machine software, it can be output through the PC software program.

SELECTION GUIDE

No. Accuracy Voltage range Current range Weight Remark
3030601 0.10% 0-264V 0-6A 12KG
3030605 0.05% 0-264V 0-6A 12KG
3031201 0.10% 0-420V 0-12A 13.5KG
3031205 0.05% 0-420V 0-12A 13.5KG
3032001 0.10% 0-420V 0-20A 18KG
3032005 0.05% 0-420V 0-20A 18KG
303H0601 0.10% 0-300V 0-6A 15KG XP system
303H0605 0.05% 0-300V 0-6A 15KG XP system
303H1201 0.10% 0-420V 0-12A 18KG XP system
303H1205 0.05% 0-420V 0-12A 18KG XP system
303H2001 0.10% 0-420V 0-20A 20KG XP system
303H2005 0.05% 0-420V 0-20A 20KG XP system

 

Additional information

Weight 15000 g

Specification

Electrical parameters
Accuracy class 0.05%, 0.1%
Power supply Single phase AC 85V-265V, 50/60 Hz
AC Voltage output
Range (U1, U2, U3 phase) 57.7V/100V/220V/380V, switch automatically (max 420V)
Adjustment resolution 0.01%, 0.1%, 1%, 10%
Accuracy 0.05% RG
Stability 0.005% RG/1min
Distortion degree better than 0.1% (not capacitive load)
Load Capacity 25VA
Full load regulation rate Less than 0.01% RG
Full load regulation time Less than 1mS
Temperature drift 8 PPM / °C
Long-term stability 60 PPM/year
AC Current output
Range (I1, I2, I3 phase) 0.1/0.25A/0.5A/1A/5A/10A/20A, switch automatically
Adjustment resolution 0.01%, 0.1%, 1%, 10%
Accuracy 0.05% RG
Stability 0.005% RG/1min
Distortion degree better than 0.1% (not capacitive load)
Load capacity 25VA
Full load regulation rate Less than 0.01% RG
Full load regulation time Less than 1mS
Temperature drift 8 PPM/°C
Long-term stability 60 PPM/year
Power output
Active power accuracy 0.05%
Reactive power accuracy 0.1%
Stability 0.005% RG/1min
Phase
Range 0°-359.99°
Adjustment resolution 0.01°, 0.1°, 1°, 10°
Accuracy 0.03° or 0.05°
Power factor
Adjusting range -1.00000 to 0 to +1.00000
Resolution 0.0001
Accuracy 0.0005
Frequency
Range 40-65Hz or 40-400Hz (option)
Adjustment resolution 0.001Hz, 0.01Hz, 0.1Hz, 1Hz
Accuracy 0.002Hz
Temperature drift 0.5PPM/°C
Long-term stability 4 PPM/year
Harmonic
Harmonic times 2-63
Adjustment resolution 0.1% (compared with fundamental wave)
Harmonic content (compared with fundamental wave)
Voltage ≤40%
Current ≤40%
Phase 0°-360°
Capacitive load capacity
0 – 280 V 1uF
280 – 420 V 0.6uF
Functions
Communication Port RS232
Programmable controlled Yes
Harmonic Yes
Wiring mode 3P4W, 3P3W, 1P2W
Key 40pcs
LCD 8.4 inch TFT color touch display
PC control software Optional
Standard
Standard IEC 62053-21,22, 23; IEC 60736; ANSI C12.20-2002;
JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019;
DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016; JJG 51-1999;
DL/T 2213.1-2021; GJB J 5857-2006; JJG6-2011; JJG70-2015;
Safety
Isolation protection IEC 61010-1:2001
Measurement Category 300 V CAT III, 600 V CAT II
Degree of protection IP20
Declaration of conformity CE & CNAS certified
Mechanical parameters
Dimensions (W×D×H) (mm) 450x380x160
Weight (kg) 18
Environmental conditions
Working temperature 0°C to 50°C
Storage conditions -30°C to 60°C
Relative humidity ≤85%