Archimed X6 Time-Resolved Real-Time PCR System

Archimed PCR instrument, Archimed is the world’s first time-resolved real-time fluorescence quantitative PCR system built by Kunpeng Gene by drawing on the essence of quantitative PCR technology development and created by an international senior technical team.

Description

Archimed is the world’s first time-resolved real-time fluorescence quantitative PCR system built by Kunpeng Gene by drawing on the essence of quantitative PCR technology development and created by an international senior technical team. The new optical path system based on Fresnel lens, patented time-resolved signal acquisition technology and unique temperature control technology enable Archimed to lead the international advanced level in terms of detection sensitivity, optical path crosstalk, temperature uniformity and accuracy. At the same time, the product design concept and manufacturing process based on a global perspective endow Archimed with excellent quality of international standards.

Additional information

Weight 100 g

Specification

 

Main Unit Specifications
Instrument Specifications Size: 350mm(L) x 520 mm (W) x 370 mm (H): Weight: 25 kg
Packing Specifications Size: 710mm(L) x 540 mm (W) x 580 mm (H): Weight: 36 kg
Model Archimed X6
Power Supply Specification Power Supply Voltage : AC 230 V
Frequency: 50 Hz:
Power: 750 w
Communication Specification USB Ports
Use Ambient Temperature: 10 °C ~ 30°C;
Humidity: 85% RH no condensation;
Atmospheric Pressure: 85.0kPa ~ 106.0 kPa;
Altitude: 2000m
Storage and Transportation Environment Temperature: -20 °C ~ 55°C; the instrument packaging in the transport box;
Humidity: 85% RH
Running Noise Maximum noise when running instrument does not exceed 60dB (A)
Thermal Parameters
Heat Cycle Peltier Semiconductor
Temperature Control Mode Temperature control module
Maximum ramp rate 3.6°C/s
Temperature Accuracy ±0.2°C
Temperature Uniformity  ±0.2°C
Optical Parameters
Excitation Source Single color LED
Detection Device High sensitivity MPPC ( silicon photomultiplier tube )
Fluorescent Channel Number 4 channels ( Archimed X4) or 6 channels ( Archimed X6)
Applicable to fluorescent Channel 1 | FAM/SYBR Green etc

Channel 2 | VIC/JOE/HEX/TET etc

Channel 3 | ROX/Texas Red etc

Channel 4 | NED/TAMRA/Cy3 etc

Channel 5 | Cy5 etc

Channel 6 | FAM/SYBR Green etc

Detection Parameters
Sample size 96 wells
Sample volume 10-50 µl
Repeatability of fluorescense intensity detection CV ≤3%
Detection of fluorescence intensity CV ≤5%
Sample repeatability CV ≤3%
Linear fluorescence intensity detection A Linear regression coefficient |r| ≥0.990 in 5 concentration gradients

 

Downloads

Request For Quotation

Enjoy Special Offer Only For You

Contact Us :