Description
Stand-alone unit after initial configuration of test parameters: The panel is capable to generate accurate test results even after days of continuous operation with no loss of data.
Single / Three Phase operation possible
Servo controlled mechanism to control current (+/- 1%) against incoming fluctuations
CT range selection for current measurement accuracy
Load selection is selector switch based: Quick and easy
PLC based timer unit (Siemens Logo) for quick and easy user interface and automated operation: Easy setting of parameters such as on time, off time, no. of cycles and threshold consecutive contact weld, contact open cycles
Accurately designed iron core inductors (Optional air core inductors as per customer specifications) for circuit parameter accuracy
Specially designed fixture for safe operation with operator safety in view
Cooling shall be provided by means of optimally placed Exhaust fans distributed all over to remove the hot air generated inside the panel cabinet.
This avoids change in circuit parameters as a result of over heating of loads
Ceramic core wire wound resistors with enamel coating: This ensures best quality of resistors that have a favourable resistance v/s temperature rise graph enabling operation for an elongated duration with accuracy
Temperature rise test can be integrated with the main endurance test
PC based option available: Complete PC data logging and control plus online plotting of temperature rise graphs