The GT6000 Mobilis is an EN15267-4 QAL1-certified (MCERTS) FTIR portable emissions analyzer for accurate, reliable, and fast multigas measurements in the field. Whether you’re conducting stack testing, on-site emissions monitoring, or combustion research, it delivers certified, lab-grade analysis without compromise. Designed to eliminate the hassle of multiple slow or hard-to-use equipment, it lets you focus on obtaining high-quality results. With portability, rugged performance, rapid response times, and powerful analysis tools, the GT6000 Mobilis provides a complete solution for efficient on-site gas analysis.
Key benefits
- The first and only FTIR analyzer with MCERTS EN15267-4 certification
- Intuitive user interface and ergonomic design
- Easy to disassemble, carry, and set-up again
- Multigas measurements in a portable package
- Realtime results reliably and remotely
- Exceptional robustness: shock and vibration resistivity by design
- Smart software with self-diagnostics for easy and fast service
- Suitable for on site or laboratory use
Product Details
Description
Measuring principle : Fourier transform infrared, FTIR
Multigas capability : Simultaneous analysis of up to 50 gas compounds
Response Time : Typically < 120 s
Power supply : 115 / 230 VAC 50 / 60Hz
Power consumption : Max. 300 W
Analysis Software : Calcmet (Required operating system Windows 10)
Data Connection : USB (HID), Ethernet, Bluetooth, WiFi Access Point and WiFi Station
Sample pump : Recommended Gasmet PSS Base or PSS Plus.
Sample gas filtration : Minimum 2 µm particulate filtration. Recommended: Gasmet PSS Base or PSS Plus with standard filter
Sample in : 6 mm Swagelok
Sample out : 8 mm Swagelok
Interferometer purge : 6 mm quick connect
Dimensions: 474 x 315 x 183 mm
Material: ABS PC
IP class: IP42
Weight : 11.2 kg
CE label : According to EMI guideline 2014/30/EU and low-voltage directive 2014/35/EU
Resolution: 4/8 cm-1
Detector: Thermoelectrically cooled MCT
Beamsplitter: Antireflection coated ZnSe
Wave number range: 900 – 4 400 cm-1
Structure: Multi-pass, fixed path length 5.0 m
Material: 100 % purity gold coated aluminum
Mirrors: 100% purity gold coated metal mirrors with protection layers
Volume: 0.5 liters
Temperature: 50 °C or 180 °C
Operating and storage conditions
Sample gas pressure : Ambient
Sample gas flow rate : Recommended: Gasmet PSS Base or PSS Plus with nominal flow of 4 l/min. If another sampling system is used, flow rate should be 2 – 8 l/min
Storage temperature : -20°C to 60°C, Non-condensing
Operating temperature : Long term -5 to 40 °C, short term -10 to 50 °C