Output Measuring AC Voltage
Available Ranges 10V 30V 100V 300V 750V auto shift
Adjustment range 0~120%Rg
Adjustment fineness Range x 0 01%
Resolution Range x 0 01%
Accuracy 0 05%Rg
Stability 0 01% 1min
Output Measuring AC Current
Available Ranges 100mA 1A 5A 10A 25A; auto shift
Adjustment range 0~120%Rg
Adjustment fineness Range x 0 01%
Resolution Range x 0 01%
Accuracy 0 05%Rg
Stability 0 01% 1min
Output Measuring AC Power
Adjustment fineness Range x 0 01%
Resolution Range x 0 01%
Accuracy 0 05%Rg Factor>0 5
Stability 0 01% 1min
Output Measuring AC Frequency
Frequency Range 45 000~65 000Hz
Adjustment fineness 0 001Hz
Accuracy 0 01%RD
Output Measuring AC Phase Angle
Phase Angle Range 0 00º~359 99º
Adjustment fineness 0 01º
Resolution 0 01
Accuracy 0 05º
Output Measuring AC Power Factor
Output Range 1 ~ 0 ~ +1
Measuring Accuracy 0 0005
Adjustment fineness 0 0001
Output Measuring Harmonic
Harmonic Setting 2~31
Harmonic Content voltage current ≤30% as against fundamental
Harmonic Output Accuracy 0 1% 1st~19th as against fundamental
0 2% 20th~31st as against fundamental
Harmonic Phase 0~360º adjustable
Measuring Electrical Energy
Measuring Accuracy 0 1%Rd PF≥0 5
Voltage Range 100V 220V 380V
Current Range 0 05~24A
Distortion of AC Outputs
Distortion <0 2% non capacitance load
Max Load Capacity of AC Voltage Current
Voltage Output 25VA max
Current Output 25VA max
Output Measuring DC voltage
Range 100mV 1V 10V 30V 100V 300V 750V
Adjustment Range 0~120%Rg 0%~110% output range at 750V
Resolution Range x 0 01%
Accuracy 0 05%Rg
Stability 0 01% 1min
Output Measuring DC current
Range 1mA 10mA 100mA 1A 5A 10A 25A
Adjustment Range 0~120%Rg
Adjustment fineness Range x 0 01%
Resolution Range x 0 01%
Accuracy 0 05%Rg
Stability 0 01% 1min
Max Load Capacity of DC Voltage Current
Voltage Output 20W max
Current Output 25W max
Power Supply Environment
Ambient Temperature 22ºC ± 1ºC
Working Temperature 0ºC~40ºC humidity≤85%RH
Nominal Input Voltage 115230Vac appointed ±10%
Nominal Frequency 5060Hz
Connection Type Standard AC socket 60320
Weight Size
Dimensions W x D x H 450mm×380mm×190mm
Weight 25kg
Ini hanya demo
Free
Ini hanya demo saja
2-3 Days
Free
Applied to Grid Corporation of measurement testing centers power companies and power plants measured ministries national institutions at all levels of measurement tests also applies to the railway petroleum chemical industry large scale industrial and mining enterprises and the meter manufacturers etc
Apply to the power sector measurement department quality inspection departments research institutions universities etc
Applies to other production and research development enterprise of energy meter power distribution terminals power management load control power quality and medium voltage reactive power compensation
Open communications protocol to facilitate the secondary development for RTU FTU Power Management Terminal Public variable measuring the terminal factory automatic verification
Calibrating a variety Analog Digital meter of direct UI instruments frequency with DCAC 0 05% accuracy and the corresponding class digital multimeter for quality inspection measurement and instrumentation maintenance parts detection
The calibrating types of test instrument including AC DC voltage meter ammeter single three phase active and reactive power meter phase meter power factor meter frequency tables synchronized tables etc
The calibrating transducer types are AC DC voltage transducer current transducer single three phase active and reactive power transmitter phase transmitter power factor transducer frequency transducer etc
The calibrating energy meter types as electronic and sensing single phase three phase active and reactive energy meter
Storage capacity up to 1 000 calibrated meters’ data
5 4 TFT LCD display touch pad and rotary encoder control PC control software also available
Brand |
Kingsine |
---|
WhatsApp Kami